Profibus Communication Connection for Parker DC590P Multi-Drive Systems

In large industrial production lines (such as steel, paper, packaging, and plastics…), synchronizing speed or tension between multiple rollers requires the use of multi-drive systems. The Parker DC590P DC drive series is a leading solution, and the Profibus network is the optimal communication method to connect them together.

Hệ thống tủ điện Multi-Drive thực tế tích hợp 4 bộ Drive Parker DC590P với các dải dòng từ 110A, 270A, 500A đến 725A truyền thông đồng bộ qua Profibus

Why Choose Profibus Communication for Parker DC590P Multi-Drive Systems ?

  • High-speed data transmission and low latency: Ensures absolute speed/torque synchronization between smaller current units (110A, 270A) up to high-capacity units such as 500A and 725A.

  • Wiring cost savings: Instead of running dozens of complex analog/digital control wires from the PLC to each individual Drive, the system only requires a single purple Profibus cable connected in a daisy-chain configuration across all stations (as can be seen from the neatly organized bus wiring system in the cable tray below in the image above).

  • Comprehensive monitoring capabilities: Enables Siemens PLCs or other Profibus-supported PLCs to easily read/write critical parameters (current, voltage, feedback speed, error codes, etc.) of each Drive to the HMI screen.

Required Equipment for Setting Up the System :

  • Parker DC590P Drives: A wide range of current ratings depending on the motor load (practical examples in this system include a mix of low and high-capacity models: 110A, 270A, 500A, and 725A).

  • Profibus Communication Card for Parker 590P: Usually the 6055-PROF-00 expansion module, plugged directly into the drive’s control board.

  • Dedicated Profibus Communication Cable (characterized by its distinctive purple color) and Profibus Connectors with a built-in terminating resistor switch (Terminator Switch).

  • Central Controller (Master): Typically a Siemens S7-300, S7-1500, or S7-1200 PLC equipped with a Profibus Master module.

4-Step Basic Connection and Configuration Procedure :

  • Step 1: Hardware Connection (Wiring): Connect the Profibus cable from the PLC to the first Drive, then daisy-chain it to the 2nd, 3rd, and 4th units. Note to flip the terminator switch to ON at the Profibus connector of the last station (e.g., the 725A or 110A unit, depending on the physical wiring layout).

  • Step 2: Set Node Address (Station Address) on the Parker 590P: Use the keypad display (the orange one shown in the image) to navigate to the SERIAL LINKS -> PROFI-BUS menu to set a unique address for each unit (e.g., Node 3, Node 4, Node 5…).

  • Step 3: Configuration in PLC Software (TIA Portal / Simatic Step 7): Import the Parker 590P GSD file into the hardware configuration. Set up the I/O memory area (Input/Output data words) for data exchange.

profibus DC590P - S7300 Siemens

  • Step 4: Configure Control Parameters on the Drive: Configure the start/stop command source and the speed setpoint source to receive data from the communication network instead of the traditional terminal blocks.

Trusted Provider for Design, Installation, and Repair of Parker DC Drive Systems

A high-capacity Multi-Drive system (110A – 725A) with Profibus communication, as shown in the image, requires an engineering team with high technical competence and genuine components.
Ky Thuat Viet Technology Co., Ltd. is proud to be the official Authorized Distributor of Parker in Vietnam.

We are committed to delivering the most optimal turnkey solutions for your factory:

  • 100% Genuine Equipment: Distributing the full range of Parker 590P DC Drives (110A, 270A, 500A, 725A…), and Profibus communication cards, complete with full CO/CQ documentation from the manufacturer.

  • In-depth Technical Expertise: A team of engineers who master the technology, specializing in designing and installing Multi-Drive speed-synchronization electrical cabinets, as well as configuring complex industrial communication networks.

  • 24/7 Repair Services: Fast diagnosis and troubleshooting of hardware and communication faults on the Parker DC590P series, minimizing factory downtime.

For solution consulting and the best price quotations, please contact us directly at:

  • Hotline / Whatsapp: +84 908353714

  • Email: info@kythuatviet.vn