Replace Fuji Frenic Mega with Parker AC20 180kW – Reliable DeviceNet & Omron PLC Integration

⚙️ Drive Upgrade – More Than Just Equipment Replacement

In systems where an Omron PLC communicates with inverters via DeviceNet, replacing a drive is not simply a matter of removing the old unit and installing a new one.

👉 In practice, to restore stable system operation, it is necessary to:

  • Understand the DeviceNet communication structure
  • Remap control data
  • Modify the Omron PLC program

🚀 Project Case: Replacing Fuji Frenic Mega with Parker AC20 180kW

We have carried out an upgrade on a system using:

  • Omron PLC with DeviceNet Master (DRM21)

plc omron - devicenet Master

  • Existing drive: Fuji Frenic Mega (DeviceNet)

frenic mega inverter


🔧 Scope of Work

🔹 1. Drive Replacement

  • Installation and configuration of Parker AC20 180kW
  • Setting up communication-based control mode

🔹 2. DeviceNet Communication Handling

  • Verification of network parameters:
    • Baud rate
    • Node ID
  • Importing and reconfiguring the device within the system

🔹 3. Omron PLC Modification

  • Editing the DeviceNet Master program
  • Remapping control data:
    • RUN/STOP command
    • Speed reference
    • Status and alarm signals

🔗 DeviceNet System Illustration (Industrial Application)

mạng devicenet công nghiệp

⚡ Results After Upgrade

✔️ Stable system operation

máy xả băng

✔️ Reliable communication between the PLC and the new drive
✔️ Accurate speed control
✔️ No communication errors encountered

ac20 parker 180kw


💡 Lessons Learned

  • DeviceNet is not plug-and-play when replacing equipment
  • Each drive manufacturer uses a different data structure
  • Both aspects must be handled:
    • Communication layer
    • PLC program

🎯 Our Services

We provide:

  • Replacement of Parker drives
  • Handling of most industrial communication protocols between drives and PLCs
  • System recovery after upgrades

Contact:

📞 Hotline: +84 908 353 714 (Mr. Lâm)

📧 Email : info@kythuatviet.vn