Parker DC590C, DC590G, and DC590P Fault Codes: Troubleshooting Guide

The Parker DC590C, DC590G, and DC590P are DC drives used in a wide range of industrial DC motor drive systems. During operation, these devices may display fault messages such as FIELD FAILED, OVER I TRIP, STALL TRIP, THERMISTOR, or SPEED FEEDBACK.

This article provides a reference table of common fault codes displayed on Parker DC Drives, helping plant maintenance personnel quickly identify fault messages, understand their possible causes, and determine appropriate initial troubleshooting procedures.

1. Parker DC590C, DC590G, and DC590P Fault Codes Reference Table

Displayed Fault Message Meaning and Possible Causes to Check
FIELD FAILED / FIELD FAIL The field current is below the required level. Check the field winding, wiring, and field supply.
FIELD OVER I Field overcurrent. Check the field current settings and field control circuit.
OVER I TRIP Armature overcurrent. Check the motor, mechanical load, power circuit, and SCRs.
STALL TRIP Motor stall or standstill condition detected by the drive’s monitoring function. Check the load, motor current, and speed feedback.
OVERSPEED Overspeed condition. Check the actual motor speed, feedback signal, and drive control configuration.
SPEED FEEDBACK / SPD FEEDBACK An abnormal condition has been detected in the speed feedback monitoring function. Check the tachogenerator, encoder, wiring, and related parameters.
ENCODER FAILED Encoder signal fault. Check the encoder power supply, signal wiring, encoder itself, and feedback configuration.
OVER VOLTS (VA) The armature voltage has exceeded the monitored limit. Check the motor speed, armature voltage, and regenerative operating conditions.
MISSING PULSE An abnormality has been detected in the armature current waveform. Check the power supply, SCR firing control circuit, and power circuit.
3 PHASE FAILED Three-phase supply fault. Check the supply voltage, fuses, and electrical connections.
PHASE LOCK Supply synchronization fault. Check the supply frequency and power quality.
HEATSINK TRIP Heatsink overtemperature. Check the cooling fan, ventilation, dust accumulation, and operating load.
THERMISTOR The motor thermal protection input has been activated. Check the motor temperature, temperature sensor, and signal wiring.
ACCTS FAILED Fault related to the AC current transformer connection to the power board. Check the connectors and associated hardware.
EXTERNAL TRIP An external trip signal has been received. Check the protection circuit, interlocks, and control inputs.
REMOTE TRIP A trip has been initiated by the remote control function. Check the control command and sequence configuration.
ENABLE LOW The enable signal does not satisfy the conditions required to enable the drive. Check the control input and interlocks.
SEQUENCING Control sequencing fault. Check the Start, Stop, and Enable signals, as well as the contactor operation.
CONTACTOR DELAY The contactor closing sequence has not completed within the expected time. Check the contactor, coil, and auxiliary feedback contacts.
SEQ PRE READY Fault related to the Pre-Ready state. Check the startup conditions and diagnostic information.
AUTOTUNE ERROR An error occurred during the autotune procedure. Check the operating conditions and control signals required for autotuning.
AUTOTUNE ABORTED The autotune procedure was aborted before completion. Check the Stop signal, Enable signal, and interlocks.
COMMS TIMEOUT Communication timeout. Check the PLC, communication cable, configuration, and status of the communicating device.
5703 RCV ERROR Data reception error associated with the communication mode using port P3. Check the connection and device configuration.
CONFIG ENABLED A run command has been issued while the drive is in configuration mode. Check the configuration status before operating the drive.
CALIBRATION TRIP Fault related to the calibration procedure. Check the configuration and follow the manufacturer’s instructions.
NO OP-STATION Fault related to the operator station under the applicable operating conditions. Check the operator station and connection cable.
AUX SUPPLY Auxiliary power supply fault. Check the auxiliary supply and associated connections.
PCB VERSION Fault related to the printed circuit board (PCB) version. Verify the model, hardware revision, and firmware version.
PRODUCT CODE Fault related to the product code or device configuration. Verify the model information against the relevant Parker documentation.

2. How to Troubleshoot a Parker DC Drive Fault

When a DC590C, DC590G, or DC590P displays a fault message, the following troubleshooting procedure is recommended:

  1. Record the exact fault message displayed on the drive’s keypad or display.
  2. Check when the fault occurred and the machine’s operating and load conditions at that time.
  3. Depending on the fault message, inspect the power supply, motor, field circuit, speed feedback system, and control signals.
  4. Refer to the technical documentation for the exact drive model to identify the possible root cause.
  5. Reset the drive and resume operation only after the relevant safety conditions have been verified and the underlying fault has been addressed.

Not every trip condition indicates that the DC Drive itself has failed. The root cause may be associated with the motor, mechanical load, power supply, wiring, sensors, or control system.

3. Technical Support for Parker DC590C, DC590G, and DC590P

Kỹ Thuật Việt provides technical support for fault diagnosis, parameter verification, and recommendations for repair or retrofit solutions for systems using Parker DC Drives.

To help us provide more accurate technical assistance, customers are advised to provide the drive model, the fault message displayed, a photo of the drive nameplate, and a description of the machine’s operating conditions when the fault occurred.

Kỹ Thuật Việt Co., Ltd. – Parker Vietnam

  • Southern Vietnam: 74/9/9–74/9/11, Street No. 9, An Hội Đông Ward, Ho Chi Minh City, Vietnam.
  • Northern Vietnam: CX2-107, Cọ Xanh 2 Street, Vinhomes Ocean Park 2, Hung Yen Province, Vietnam.
  • Hotline: +84 908 353 714
  • Email: info@kythuatviet.vn
  • Website: https://parkervietnam.com/